Fire Inspect Hub is inspection software built for NFPA 2001 clean-agent suppression systems — the FM-200, Novec 1230, and Inergen systems protecting data centers, server rooms, telecom, and archives. Every checklist item references the NFPA 2001 (2022) Chapter 11 section it inspects against, and the system computes container agent-loss for you. Professional report, same day.
Last updated June 2026 — built on the NFPA 2001 (2022) edition, Chapter 11, with the full monthly / semiannual / annual ITM program and automatic container weight-loss flagging.
No credit card required
Clean-agent systems guard data centers, server rooms, telecom closets, and archives — spaces where a water-based discharge would do as much damage as the fire. Clean agent inspection software has to handle the whole range of special-hazard suppression agents: halocarbons like FM-200 (HFC-227ea) and Novec 1230 (FK-5-1-12), inert blends like Inergen (IG-541), and CO2 systems. NFPA 2001 ITM isn't one annual checkbox: it's a tiered program — monthly visual, semiannual container service, annual functional test — plus per-container agent-loss math against the nameplate charge.
Generic inspection apps force everything into a single frequency and leave agent-loss as a manual chart lookup the inspector does by hand. That's exactly the part that's easy to get wrong on the system you most need to be right. If you're weighing tools, our comparison of fire inspection software covers where a special-hazard workflow like this fits — and clean-agent systems are triggered by detection, so the same platform should also handle your fire alarm inspections.
NFPA 2001 is the Standard on Clean Agent Fire Extinguishing Systems. Clean agents — FM-200 (HFC-227ea), Novec 1230 (FK-5-1-12), Inergen (IG-541), CO2, and legacy Halon 1301 — suppress fire without water or residue, which is why they protect electronics and irreplaceable assets.
If your customer has a clean-agent system, NFPA 2001 inspection, testing, and maintenance applies — and those systems live in data centers and server rooms, telecom and network closets, electrical and control rooms, and museum, library, and records archives.
Most tools force every inspection into one frequency. NFPA 2001 doesn't work that way — and Fire Inspect Hub models each cadence as its own inspection record under the same clean-agent system. Start a monthly today and a semiannual next week; they're separate records, not one overwritten form.
Releasing panel powered and clear of supervisory, trouble, and alarm conditions; manual controls accessible; no physical damage; container gauges within the operable range; protected hazard unchanged from design; prior deficiencies corrected.
Listed agent-quantity measuring devices, container inspection tags updated, and compliant agent handling — plus the per-container weight and pressure measurements that drive the agent-loss compute below.
Full functional operation test by qualified personnel, system hoses examined, and the enclosure (room) inspected for barrier integrity so the space still holds design concentration.
System kept in full operating condition, any actuation reported to the AHJ, impairments handled per the impairment program, and enclosure penetrations sealed to the original fire-resistance rating.
Personnel expected to inspect, service, test, or maintain the system are trained and current in their functions — captured as part of the program record.
Each cadence is its own record under one system asset — so a monthly and a semiannual coexist instead of overwriting each other. The multi-cadence handling is the part most inspection tools simply don't have.
Here's what no other inspection tool — content site or software — does for NFPA 2001: it computes container agent loss and flags the deficiency for you. Your inspector records the cylinder's measured weight; Fire Inspect Hub does the §11.3 math against the nameplate charge.
That's the difference between a checklist that records what the inspector decided and a system that does the §11.3 math with them.
Every deficiency carries a severity and its NFPA 2001 (Chapter 11) section reference — and the agent-loss finding is computed, not hand-judged:
Container agent loss greater than 5% of the nameplate charge — auto-flagged from the recorded weight.
Releasing panel showing supervisory, trouble, or alarm — not powered and clear.
Container pressure gauge reading outside the operable range.
Annual functional operation test not performed by qualified personnel.
Enclosure changes affecting agent-concentration retention left uncorrected.
Enclosure penetrations not sealed to restore the original fire-resistance rating.
Every item cites its NFPA 2001 (2022) Chapter 11 section, so the AHJ sees exactly what standard each line was inspected against.
Per-container weight loss computed against the nameplate charge, with the critical-deficiency threshold applied automatically — the math is on the report, not in someone's head.
Monthly, semiannual, and annual inspections each generate their own dated record under the system — the tiered NFPA 2001 program, documented as it actually runs.
Pass · Non-Critical Deficiency · Critical Deficiency · Impairment — the terminology your AHJ and insurer recognize.
NICET level, state license jurisdiction, and license number render under the inspector's signature on every report.
A branded, client-ready PDF generates the moment the inspection is finalized. No office cleanup, no reformatting.
The system or item meets the applicable NFPA 2001 requirement. No action required.
A deficiency exists but does not have an immediate adverse effect on system performance. Attention needed — not urgent.
A deficiency that adversely affects system performance and requires immediate attention.
Full-stop escalation. The system is out of service. Notify the building owner and AHJ immediately.
The inspector always determines the compliance level. Fire Inspect Hub provides the framework — and the agent-loss computation — but the professional judgment belongs to the inspector.
Fire Inspect Hub is purpose-built for fire protection contractors who inspect NFPA 2001 clean-agent systems — and for the facilities that depend on them. If you're forcing a multi-cadence clean-agent program into a single-frequency tool and doing the agent-loss math by hand, this was built for you.
No credit card. No time limit. Free plan reports are marked as samples and aren't for compliance submission. Upgrade for client-ready reports.
Start FreeMonth-to-month. No contract. Cancel anytime.
Start For FreeLarger teams or multiple locations? Let's build you a quote.
Let's talkClean-agent suppression (NFPA 2001), spray application (NFPA 33), and dipping / coating / printing (NFPA 34) are all built into the platform today — one login, one workflow, one report format. NFPA 2001 is the suppression standard that NFPA 33 and 34 booth and process inspections cross-reference out to.
Start for free. No credit card required. Run a complete NFPA 2001 clean-agent inspection in your first session — and watch the agent-loss math run itself.
No credit card required